PERFORMANCE
Voltage: nominal 12/24V
Voltage: operating 12/24V
Signal Source: Engine Electronic Control Module (ECM)

 

VIBRATION
Operating:
0.5G
Storage:
50G

 

TRANSIENT VOLTAGE
Withstands voltage transients of 200 Volts for 300 microseconds duration (SAE J1810)

 

OVER VOLTAGE PROTECTION
Tested with a supply voltage for 20 Volts for 1 hour.
Reverse polarity protected.

 

CORROSIVE GAS
NOT ACCEPTABLE.

 

 

TEMPERATURE
Tested at the following operating ranges:

A. If being used as a rear engine run box Operating:
-4°F to 158°F
Storage:
-22°F to -176°F
(-30°C to 80°C)
B. For use as a diagnostic tool Operating:
32°F to 122°F
Storage:
-4°F to 158°F
(-20°C to 70°C)

 

SHOCK
Operating:
3G
Storage:
50G

 

LOAD DUMP
Meets (SAE J113) three positive 80 Volt transients with one minute intervals.

 

SALT SPRAY
NOT ACCEPTABLE.

 